The new StormTech SC-800 Chamber
|
|
|
There’s many reasons why ADS StormTech is the world’s preferred below ground SuDS attenuation
system – now there’s one more.
The ADS StormTech SC-800 chamber is now available in the UK. It holds more water than the best-selling SC-740 chamber, and requires less embedment stone for installation. The corrugated design reduces the minimum cover depth and delivers a 7% smaller footprint than the SC-740 for the same storage volume.
|
|
|
|
|
|
|
|
|
Other below-ground SuDS attenuation systems such as crates and pipes, do not provide any treatment to the incoming flow. StormTech directs first flush runoff into the patented Isolator Row – an integral water quality treatment device. ADS StormTech with Isolator Row is the first combined SuDS attenuation and water quality management system to have 3rd party verified Mitigation Indices (MIs). StormTech’s MIs provide TSS=0.8; Metals=0.6: Hydrocarbons=0.7 making it suitable for applications with medium pollution hazard indices without the need for additional costly SuDS treatment components.
|
|
|
|
|
|
|
|
|
|
|
|
|
Many policy documents from SuDS adopting bodies mandate ‘green’ SuDS. However, a recent article in Drain Trader highlighted the need to balance ‘green’ with ‘grey’ SuDS components for solutions that are more technically, environmentally and economically viable over the lifetime of the development. ADS StormTech can be a key part of this approach.
|
|
|
|
|
|
|
|
|
|
|
|
|
StormTech offers comprehensive technical support for design, installation and maintenance, 24/7, 365 days a year. Our new online Design Tool offers improved UK navigation and generates site-specific layouts, which can be integrated with CAD and other design, specification and submittal documents. It's free to use and even gives you a schedule of materials as part of the design output, so you can prepare estimates in minutes. Click here to visit our Design Tool.
|
|
|
|
|
|
|
|
|
|
|
|
|
Geocellular crates are generally regarded as difficult to clean effectively and prone to silting. The CIRIA SuDS Manual C753 suggests that such systems may require an additional 10% in storage volume to offset this loss – something that is often overlooked. Of particular interest to adopting bodies, ADS StormTech is easy to inspect and maintain. Only Isolator Row requires cleaning, typically every 2 – 5 years, using standard sewer cleaning equipment
|
|
|
|
|
|
|
|
|
|
No wonder that ADS StormTech is the world’s leading proprietary subsurface stormwater attenuation system. Compared to traditional alternatives, the benefits are substantial.
|